rtems_status_code rtems_timer_fire_after( rtems_id id, rtems_interval ticks, rtems_timer_service_routine_entry routine, void *user_data );
RTEMS_SUCCESSFUL
- timer initiated successfully
RTEMS_INVALID_ADDRESS
- routine
is NULL
RTEMS_INVALID_ID
- invalid timer id
RTEMS_INVALID_NUMBER
- invalid interval
This directive initiates the timer specified by id. If the timer is running, it is automatically canceled before being initiated. The timer is scheduled to fire after an interval ticks clock ticks has passed. When the timer fires, the timer service routine routine will be invoked with the argument user_data.
This directive will not cause the running task to be preempted.