ER ercd =trcv_mbf( VP msg, INT *p_msgsz, ID mbfid, TMO tmout );
E_OK
- Normal Completion
E_ID
- Invalid ID number (mbfid was invalid or could not be used)
E_NOEXS
- Object does not exist (the message buffer specified by
mbfid does not exist)
E_OACV
- Object access violation (A mbfid less than -4 was
specified from a user task. This is implementation dependent.)
E_PAR
- Parameter error (values unsuitable for msg; tmout is -2
or less)
E_DLT
- The object being waited for was deleted (the specified
message buffer was deleted while waiting)
E_RLWAI
- WAIT state was forcibly released (rel_wai was received
while waiting)
E_TMOUT
- Polling failure or timeout
E_CTX
- Context error (issued from task-independent portions or a
task in dispatch disabled state)
EN_OBJNO
- An object number which could not be accessed on the
target node is specified.
EN_PAR
- A value outside the range supported by the target node
and/or transmission packet format was specified as a parameter (a value
outside supported range was specified for tmout)
EN_RPAR
- A value outside the range supported by the issuing node
and/or transmission packet format was returned as a return parameter (msgsz is outside supported range for requesting node)
The trcv_mbf
system call has the same function as rcv_mbf
with an additional timeout feature. A maximum wait time (timeout value)
can be specified using the parameter tmout
. When a timeout is
specified, a timeout error, E_TMOUT
, will result and the system
call will finish if the period specified by tmout
elapses without
conditions for releasing wait being satisfied (i.e. without a message
arriving).
Only positive values can be specified for tmout
. Specifying
TMO_POL
= 0 to trcv_mbf
for tmout
indicates that a
timeout value of 0 be used, resulting in exactly the same processing as
prcv_mbf
. Specifying TMO_FEVR
= -1 to trcv_mbf
for
tmout indicates that an infinite timeout value be used, resulting in
exactly the same processing as rcv_mbf
.
Multiprocessing is not supported. Thus none of the "EN_" status codes will be returned.