OAR

RTEMS 4.5.1-pre3 On-Line Library


Event Manager Building an EVENT_RECEIVE Option Set

PREV UP NEXT Bookshelf RTEMS C User's Guide

11.2.3: Building an EVENT_RECEIVE Option Set

In general, an option is built by a bitwise OR of the desired option components. The set of valid options for the rtems_event_receive directive are listed in the following table:

Option values are specifically designed to be mutually exclusive, therefore bitwise OR and addition operations are equivalent as long as each option appears exactly once in the component list. An option listed as a default is not required to appear in the option list, although it is a good programming practice to specify default options. If all defaults are desired, the option RTEMS_DEFAULT_OPTIONS should be specified on this call.

This example demonstrates the option parameter needed to poll for all events in a particular event condition to arrive. The option parameter passed to the rtems_event_receive directive should be either RTEMS_EVENT_ALL | RTEMS_NO_WAIT or RTEMS_NO_WAIT. The option parameter can be set to RTEMS_NO_WAIT because RTEMS_EVENT_ALL is the default condition for rtems_event_receive.


PREV UP NEXT Bookshelf RTEMS C User's Guide

Copyright © 1988-2000 OAR Corporation